Structured cabling system: a compliance assessment in a healthcare facility
DOI:
https://doi.org/10.19180/1809-2667.v28n22026.23631Keywords:
structured cabling system, technical standards, therapy center, cable analyzerAbstract
This study aimed to evaluate the compliance of a Structured Cabling System (SCS) in a center specialized in neurodevelopmental disorders therapy located in the city of Campos dos Goytacazes, RJ, considering the current technical standards. The research was conducted through a bibliographic review in the scientific databases Scopus, Web of Science and Google Scholar, in addition to the analysis of the standards pertinent to the subject. The methodology also included an on-site technical inspection and acceptance tests of the building's horizontal cabling, using a cable analyzer. The results revealed the absence of a telecommunications room on the ground floor, lack of identification in all telecommunications outlets and several failures related to the transmission parameters and the electrical network of the cables. These findings allow the proposal of targeted corrective interventions, contributing to the improvement of the building's telecommunications infrastructure and ensuring compliance with the applicable technical standards.Downloads
References
ABNT. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 14565: Cabeamento estruturado para edifícios comerciais. 6. ed. Rio de Janeiro: ABNT, 2025. 69 p.
ABNT. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 16415: Caminhos e espaços para cabeamento estruturado. 2. ed. Rio de Janeiro: ABNT, 2021. 46 p.
ACATAUASSU, D.; COSTA, J. C. W. A. Refining worst-case crosstalk models for the next generation broadband over copper. In: 2017 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC), 2017. Anais […]. Águas de Lindoia: IEEE, 2017. p. 1-4. DOI: https://doi.org/10.1109/IMOC.2017.8121067. Disponível em: http://ieeexplore.ieee.org/document/8121067/. Acesso em: 18 fev. 2025.
BARBOZA, M. Normas para cabeamento estruturado. Clarity Treinamentos, 1 abr. 2026. Disponível em: https://brown-capybara-561275.hostingersite.com/normas-para-cabeamento-estruturado/. Acesso em: 11 maio 2026.
BENSIAMMAR, S.; LEFOUILI, M.; BELKHELFA, S. Equivalent cable harness method generalized for predicting the electromagnetic emission of twisted-wire pairs. Electrical Engineering & Electromechanics, Jijel, v. 1, n. 2, p. 29-34, 2022. DOI: https://doi.org/10.20998/2074-272X.2022.2.05. Disponível em: http://eie.khpi.edu.ua/article/view/254745. Acesso em: 11 fev. 2025.
BONORA, A. N.; GIMENEZ, E. J. C.; PINA, E. G.; SILVA, L. F. C.; TELLAROLI, R. L. Valores normalizados dos parâmetros de cabeamento estruturado metálico na certificação de redes. Revista Científica Periódica - Telecomunicações, Santa Rita do Sapucaí, v. 5, n. 2, p. 37-43, 2002. Disponível em: https://inatel.br/revista/documents/2002/vol05-n02/6-valores-normalizados-dos-parametros-de-cabeamento-estruturado-metalico-na-certificacao-de-redes.pdf. Acesso em: 12 maio 2026.
CAICEDO, F.; ALPÚSIG, S.; CAIZA, J.; AZOGUE, J. Rehabilitation of the Data Network and Computer Systems of Community Radio, Case Study Radio Latacunga. In: 2023 IEEE SEVENTH ECUADOR TECHNICAL CHAPTERS MEETING (ECTM), 10 out. 2023. Anais […]. Ambato: IEEE, 2023. p. 1-5. DOI: https://doi.org/10.1109/ETCM58927.2023.10309030. Disponível em: https://ieeexplore.ieee.org/document/10309030/. Acesso em: 19 dez. 2025.
COLLINS, C. J.; BRAY, J. R. Worst-Case Crosstalk Measurements of Cables - The Multinetwork Analyzer Method. IEEE Transactions on Electromagnetic Compatibility, Kingston, v. 60, n. 4, p. 1061-1068, 2018. DOI: https://doi.org/10.1109/TEMC.2018.2791342. Disponível em: https://ieeexplore.ieee.org/document/8269412. Acesso em: 10 mar. 2025.
FLUKE CORPORATION. Manual de Resolução de Falhas em Cabeamentos de Cobre. 2008. Disponível em: https://sistest.com.br/site/wp-content/uploads/2016/08/DTX-Manual-de-Resolu%C3%A7%C3%A3o-de-Falhas-em-Cabeamentos-de-Cobre.pdf. Acesso em: 26 mar. 2025.
FLUKE NETWORKS. Cabos de alumínio cobreado (CCA). Fluke Networks, 2022. Disponível em: https://pt.flukenetworks.com/content/application-note-copper-clad-aluminum-cables. Acesso em: 10 mar. 2025.
KAVUN, S.; ZAMULA, A.; MIKHEEV, I. Calculation of expense for local computer networks. In: PROBLEMS OF INFOCOMMUNICATIONS. SCIENCE AND TECHNOLOGY (PIC S&T), INTERNATIONAL SCIENTIFIC-PRACTICAL CONFERENCE, 4., 2017. Proceedings […]. Kharkov: IEEE, 2017. p. 146-151. Disponível em: http://ieeexplore.ieee.org/document/8246369/. Acesso em: 15 fev. 2025.
ISO; IEC. International Organization for Standardization; International Electrotechnical Commission. ISO/IEC 11801:2017: Information technology — Generic cabling for customer premises. Genebra: ISO/IEC, 2017. Disponível em: https://www.iso.org/standard/66182.html. Acesso em: 17 mar. 2025.
ISO; IEC. International Organization for Standardization; International Electrotechnical Commission. ISO/IEC 27002:2022: Information security, cybersecurity and privacy protection — Information security controls. Genebra: ISO/IEC, 2022. Disponível em: https://www.iso.org/standard/75652.html. Acesso em: 16 fev. 2025.
MARIN, P. S. Cabeamento Estruturado. 2. ed. São Paulo: Editora Érica, 2020. (Série Eixos)
MIŠKOVIĆ, A.; NEDIC, V.; BANKOVIC, N. Implementation of ISO / IEC 11801-1: 2017 standard in constructing internal and external network infrastructure. In: NATIONAL CONFERENCE, 23.; INTERNATIONAL CONFERENCE, 9., 2021, Kopaonik, Serbia. Proceedings […]. Kopaonik: Association for Quality and Standardization, 2021. Disponível em: https://www.researchgate.net/publication/352179561_IMPLEMENTATION_OF_ISO_IEC_11801-1_2017_STANDARD_IN_CONSTRUCTING_INTERNAL_AND_EXTERNAL_NETWORK_INFRASTRUCTURE. Acesso em: 9 mar. 2025.
MOTA, T. C.; BARRETO, P. R. R. Análise de parâmetros de transmissão de cabos de par trançado. In: SIMPÓSIO DE ENGENHARIA DE PRODUÇÃO - SIMEP, 11., 2023, Campina Grande (PB). Anais […]. Campina Grande, PB: SIMEP, 2023. DOI: https://doi.org/10.29327/11simep.612050. Disponível em: https://www.even3.com.br/anais/11simep/612050. Acesso em: 2 dez. 2025.
MUSA, M. A. F.; ZAMANI, N. S.; ASROKIN, A.; HASHIM, N.; SAID, W. M. I. W. M.; ABIDIN, A. N. Z. FEXT and NEXT analysis for VDSL2 technology on 50 twisted pairs TM copper cable. In: 2015 IEEE MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 12., 2015, Kuching, Malaysia. Proceedings […]. Kuching, Malaysia: IEEE, 2015. p. 175-180. DOI: https://doi.org/10.1109/MICC.2015.7725429. Disponível em: http://ieeexplore.ieee.org/document/7725429/. Acesso em: 10 mar. 2025.
MUSTAM, S. M.; ILYAS, M. A.; YAZED, M. S. M.; ALAM, C. K. A. C. K. Impact of twisting rate in 10 pairs of unshielded twisted-pair copper cables on insertion loss and crosstalk coupling for G.fast technology. Bulletin of Electrical Engineering and Informatics, Johor, v. 9, n. 2, p. 669-675, 2020. DOI: https://doi.org/10.1109/MICC.2015.7725429. Disponível em: https://beei.org/index.php/EEI/article/view/1873. Acesso em: 10 fev. 2025.
PESSANHA, E. P.; BARRETO, P. R. R. Proposta de modelo para o dimensionamento de sistemas de cabeamento estruturado. Vértices (Campos dos Goitacazes), v. 25, n. 1, e25119085, 2023. DOI: https://doi.org/10.19180/1809-2667.v25n12023.19085. Disponível em: https://essentiaeditora.iff.edu.br/index.php/vertices/article/view/19085. Acesso em: 7 abr. 2025.
POGORELSKIY, S.; GRIGORYAN, E.; KOCSIS, I. BIM-Based Approach for Low-Voltage Line Design and Further Operation. Applied Sciences, Basileia, v. 15, n. 17, 9296, 2025. DOI: https://doi.org/10.3390/app15179296. Disponível em: https://www.mdpi.com/2076-3417/15/17/9296. Acesso em: 19 dez. 2025.
POGORELSKIY, S.; KOCSIS, I. Designing structured cabling systems documentation and model by using Building Information Modeling – Literature review. Annales Mathematicae et Informaticae, Eger, v. 60, p. 121-132, 2024. DOI: https://doi.org/10.33039/ami.2024.02.005. Disponível em: https://publikacio.uni-eszterhazy.hu/7976/. Acesso em: 19 dez. 2025.
PRYSMIAN GROUP. Telecoms - Multimedia & Enterprise Networks. Prysmian. 2019. Disponível em: https://www.prysmian.com/sites/www.prysmian.com/files/2024-02/UC-CU-Matrix-WEB-ver-%202-3.pdf. Acesso em: 27 fev. 2025.
SANOUSSI, B.; DOSSOU, M.; MOÏSE, O.; BIDOSSESSI, A. Role of the structured cabling on the performance of a university intranet: the case study of Polytechnic School of Abomey-Calavi. In: E-AGE ANNUAL CONFERENCE, 2020: Groundbreaking research and education networks. Proceedings […]. Abu Dhab: ASREN, 2020. p. 1-8. Disponível em: https://www.researchgate.net/publication/351939241. Acesso em: 9 mar. 2025.
SEMENOV, A. Advanced Twisted Pair Cables for Distributed Local Area Networks in Intelligent Structure Systems. IOP Conference Series: Materials Science and Engineering, Incheon, v. 317, n. 1, p. 012053, 2018. DOI: https://doi.org/ 10.1088/1757-899X/317/1/012053. Disponível em: https://iopscience.iop.org/article/10.1088/1757-899X/317/1/012053. Acesso em: 13 maio 2026.
SEMENOV, A. B.; SIDNEV, S. A.; TSARENKO, V. A. A Mathematical Model of the Process of Technical Operation of the Data Center Information Cable System According to the “On Demand” Scheme. In: 2024 SYSTEMS OF SIGNALS GENERATING AND PROCESSING IN THE FIELD OF ON BOARD COMMUNICATIONS, 12 mar. 2024, Moscou. Proceedings […]. Moscow: IEEE, 2024. p. 1-5. DOI: https://doi.org/10.1109/IEEECONF60226.2024.10496783. Disponível em: https://ieeexplore.ieee.org/document/10496783/. Acesso em: 19 dez. 2025.
WANG, B.; YUE, W. Parametric design method of building structured cabling system oriented to data mining. IET Networks, Hoboken, , p. ntw2.12070, 19 nov. 2022. DOI: https://doi.org/10.1049/ntw2.12070. Disponível em: https://ietresearch.onlinelibrary.wiley.com/doi/10.1049/ntw2.12070. Acesso em: 17 dez. 2025.
WU, Z.; YANG, Z.; MUEED, A.; KHAN, S.; USMAN, B; ASIF, M. Computational Analysis of Shielded Twisted Pair Cable Based on MoM-MLFMM Algorithm. In: INTERNATIONAL CONFERENCE ON ENGINEERING AND EMERGING TECHNOLOGIES (ICEET), 7., 2021, Istanbul, Turkey. Proceedings […]. Istanbul, Turkey: IEEE, 2021. p. 1-6. DOI: https://doi.org/10.1109/ICEET53442.2021.9659583. Disponível em: https://ieeexplore.ieee.org/document/9659583/. Acesso em: 10 mar. 2025. https://doi.org/10.1109/ICEET53442.2021.9659583
YING, P. A Computer Aided Wiring Scheme for Intelligent Building. Journal of Physics: Conference Series, Fenghuang, v. 2717, 012039, mar. 2024. DOI: https://doi.org/ 10.1088/1742-6596/2717/1/012039. Disponível em: https://iopscience.iop.org/article/10.1088/1742-6596/2717/1/012039. Acesso em: 19 dez. 2025.
YUE, C.; WANG, L.; SHEN, P. Health Evaluation of Train Ethernet Cable Based on Health Factor Penalty Algorithm. In: LIANG, J.; JIA, L.; QIN, Y.; LIU, Z.; DIAO, L.; AN, M. (ed.). Proceedings of the 5th International Conference on Electrical Engineering and Information Technologies for Rail Transportation (EITRT) 2021: Rail Transportation Information Processing and Operational Management Technologies. Singapore: Springer Singapore, 2022. p. 1-9. (Lecture Notes in Electrical Engineering, v. 867). DOI: https://doi.org/10.1007/978-981-16-9909-2_1. Disponível em: https://link.springer.com/10.1007/978-981-16-9909-2_1. Acesso em: 25 mar. 2025.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Paulo Cesar Barcelos da Silva Filho, Plínio Rodrigues Rosa Barreto

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors of the manuscript submitted to Vértices, hereby represented by the corresponding author, agree to the following terms:
The authors retain the copyright and grant Vértices the right of first publication.
At the same time the work is licensed under the Creative Commons Attribution 4.0 International License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon its content for any legal purpose, even commercially, provided the original work is properly cited.
Authors will not receive any material reward for the manuscript and Essentia Editora will make it available online in Open Access mode, through its own system or other databases.
Authors are authorized to enter into additional contracts separately for non-exclusive distribution of the version of the work published in Vértices (eg, publish in institutional repository or as book chapter), with acknowledgment of authorship and initial publication in this journal.
Authors are permitted and encouraged to disseminate and distribute the post-print (ie final draft post-refereeing) or publisher's version/PDF at online information sources (eg, in institutional repositories or on their personal page) at any time after the first publication of the article by Vértices.
Essentia Editora may make normative, orthographic and grammatical changes in the originals in order to maintain the standard language, with the final consent of the authors.
The content and opinions expressed in the manuscript are the sole responsibility of the author (s).
















1.png)